Structural Standards
- 160 & 175 Wind Load (Speed)
- 2 x 10 Treated Floor Joist 16” On Center
- Joist Hangers with Strap Nails on All Floor Joist
- 2 x 12 Treated Triple Perimeters
- Two Layers 23/32” (3/4”) Non Treated Plywood Floors Tongue & Grooved
- NOTE: Plywood Floors are Glue & Screwed (NO NAILS)
- Pre-Engineered Roof Trusses 16” On Center w/Hurricane Fasteners
- 5/12 Roof Pitch Only Per Code
- Single 26 Gauge Uplift Straps All Perimeter Wall Studs for 160 Wind Load Models
- Double 26 Gauge Uplift Straps All Perimeter Wall Studs for 175 Wind Load Models
- 1 ½” Microllam Beam at All Mate Line Spans
- 5/8” Plywood (Non Treated) Roof Decking with Expansion Clips
- 5/8” Plywood (Non Treated) Wall Sheathing Glued & Fastened to Wall Studs
- Housewrap - Forced per D.C.A. Code
- 10 Year Structural Warranty Home Buyers Warranty
Exterior Standards
- 2 x6 Wall Studs Single Bottom & Double Top Plate
- Exterior Wall Studs 16” On Center
- 12” Eave Overhang 6 ¾” Hardiboard Fascia & Hardiboard Soffit
- Hardiboard Fascia has ¾” Bottom Lip
- Continuous Ridge Vent
- Architectural Asphalt Shingle 30 year Warranty
- 4.5” Dutch Lap Vinyl Siding Owens Corning - .040 Mil
- Black Matte Finished Coach Lights at All Entrances
- 1” X 6” Hardiboard Trim Around All Windows
- Doors: Front 1 ¾” 6 Panel Steel Insulated - Out Swing
- Doors: Rear 1 ¾” Cottage Steel Insulated - Out Swing
- G.F.I. Receptacles Front & Rear of Home
- Two Water Faucet Front & Rear of Home
- DP-80 38” x 66” West Windows Double Hung No Mullions
- DP-80 30” x 40” West Windows Double Hung No Mullions
Interior Standards
- 2 x 4 Interior Wall Studs 16” On Center
- ½” Drywall Glued & Screwed to Wall Studs
- 8 Foot Flat Ceilings Throughout Popcorn Finish
- ½” Drywall Ceiling Panels Glued & Screwed
- 12” x 12” V.T.C. Hand Laid Tile All Wet Areas
- Pre-Hung Cathedral Style Interior Doors White
- 34 Ounce Shaw Carpet ½” Rebond Pad with Tack Strip
- Closet Maid Shelving Closets, Pantry & Utility
- Residential Light Fixtures (Brushed Nickel Finish)
Kitchen Standards
- Wilson Art (High Definition)Countertops
- Countertops Rolled Edge with Backsplash
- 8 1/2” Deep Double Stainless Steel Sink
- Goose Neck Faucet with Sprayer (Brushed Nickel)
- Solid Wood Cabinets with Hidden Hinges
- Cabinets (White & Flat Panel Maple) Standard
- Brushed Nickel Handles/Knobs on Doors & Drawers (White Cabinets Only)
- Recessed Fluorescent Light (Kitchen & Utility)
- Recessed Can Lights (For Locations refer to Home Plans)
- 30” Electric Range with Ventless Range Hood
Bath Standards
- Ventilating Fans with Lights
- Cultured Marble Countertops
- 60” One Piece Fiberglass Tub/Shower Combination
- Tub/Shower Faucet Brushed Nickel with Temperature Control
- Elongated Toilets: 1.6 Gallons per Flush
- Double Lavatories Master Bathroom (Most Models)
- Solid Wood Cabinets with Hidden Hinges
- Bathroom Cabinets White Standard
Electrical & Plumbing Standards
- All Electrical Meets or Exceeds N.E.C. Code
- Smoke Detectors Per Code
- G.F.I. Protected Receptacles in Wet Areas Per Code
- 200 Amp Panel Box 40 Slot Panel Box
- Washer/Dryer Hookup
- C.P.V.C. Fresh Water Lines with Main Shut Off Valve
- Water Cutoffs At All Supply Lines
- P.V.C Plumbing Waste Lines
- (Waste Lines Installed above Floor Only & Stubbed Out Below)
- G.F.I Electrical Outlet located under Home
- Standard Electrical Junction located under Home
- 3-Way Switch located at Main Entrance Door for Future Stairway Light
- Prep for Updraft Furnace
Energy Efficiency Standards
- 40 Gallon Quick Recovery Electric Water Heater
- Insulation R-19 Exterior Walls & R-38 Roof
- No Floor Insulation or Black Bottom Board
- H.V.A.C. Overhead Duct Work with Insulated Supply Lines
- 12” Supply Lines & 14” Return Lines