Structual Standards
- 140 Wind Load (Speed) Minimum All Homes
- 2 x 10 Floor Joist 16” On Center
- 2 x 10 Double Perimeter
- 19/32” (5/8”) Plywood Floors Tongue & Grooved
- NOTE: Plywood Floors are Glue & Screwed (NO NAILS)
- Pre-Engineered Roof Trusses 16” On Center w/Hurricane Fastners
- 26 Gauge Uplift Straps All Perimeter Wall Studs
- 1 ½” Microllam Beam at All Mate Line Spans
- 7/16” O.S.B. Roof Decking with Expansion Clips
- 7/16” O.S.B. Wall Sheathing Glued & Fastened to Wall Studs
- Housewrap - Forced per D.C.A. Code
- 10 Year Structural Warranty Home Buyers Warranty
Exterior Standards
- 2 x 6 Exterior Wall Studs 16” On Center
- 12” Eave Overhang 6” Fascia with Vented Vinyl Soffit
- Continous Ridge Vent
- Architectural Asphalt Shingle 30 year Warranty
- Hardi Lap-Siding
- Black Matte Finished Coach Lights at All Entrances
- 14” Raised Panel Shutters on Front Elevation
- Doors: Front 1 ¾” 6 Panel Steel Insulated
- Doors: Rear 1 ¾” Cottage Steel Insulated (optional)
- G.F.I. Receptacles Front & Rear of Home
- Two Water Faucet Placement will change with each model
- Kinro DP-66 Windows with Mullions - Double Pane
Interior Standards
- 2 x 4 Interior Wall Studs 16” On Center
- ½” Drywall Glued & Screwed to Wall Studs
- 8 Foot Flat Ceilings Throughout Orange Peel Finish
- ½” Drywall Ceiling Panels Glued & Screwed
- Pre-Hung Cathedral Style Interior Doors White
- 24 Ounce Shaw Carpet ½” Rebond Pad with Tack Strip
- Closet Maid Shelving Closets, Pantry & Utility
- Residential Light Fixtures (Brushed Nickel Finish)
Kitchen Standards
- Wilson Art (High Definition)
- CountertopsCountertops Rolled Edge with Backsplash
- 8 1/2” Deep Double Stainless Steel Sink
- Goose Neck Faucet with Sprayer (Stainless Steel)
- Solid Wood Cabinets with Hidden Hinges
- Oak Cabinets
- Brushed Nickel Handles/Knobs on Doors & Drawers
- 30” Electric Range with Ventless Range Hood
Baths Standards
- Ventilating Fans
- Wilson Art (High Definition) Countertops
- Countertops Rolled Edge with Backsplash
- 60” One Piece Fiberglass Tub/Shower Combination
- Tub/Shower Faucet Brushed Nickel with Anti-Scold Valve
- Elongated Toilets: 1.6 Gallons per Flush
- Double Lavatories Master Bathroom (Most Models)
- Solid Wood Cabinets with Hidden Hinges
- Bathroom Cabinets White Standard
Electrical & Plumbing Standards
- All Electrical Meets or Exceeds N.E.C. Code
- Smoke Detectors Per Code
- G.F.I. Protected Receptacles in Wet Areas Per Code
- 200 Amp Panel Box 40 Slot Panel Box
- Washer/Dryer Hookup
- C.P.V.C. Fresh Water Lines with Main Shut Off Valve
- Water Cutoffs At All Supply Lines
- P.V.C Plumbing Waste Lines
- (Waste Lines Installed above Floor Only & Stubbed Out Below)
Energy Efficiency Standards
- 50 Gallon Quick Recovery Electric Water Heater
- Insulation R-11 Floor, R-19 Exterior Walls & R-22 Roof
- H.V.A.C. Overhead Duct Work with Insulated Supply Lines
- 12” Supply Lines & 14” Return Lines